24/7/365 emergency response for Gulf Coast plantsCall 281-991-7726

API 611 and API 612 Steam Turbines

Shin Nippon Machinery mechanical drive and generator drive steam turbines for refining, petrochemical, fertilizer and power plants, supplied and serviced in North America by PPS.

Mechanical drive turbines (API 611)

The H series and the high output, high speed HO series are compact single stage horizontal turbines. The CC series handles high speed compressor drives, and the V series is a vertical design. They are the standard choice for driving pumps, compressors, blowers and fans in hydrocarbon plants.

Shin Nippon Machinery API 611 vertical mechanical drive steam turbine in the factory

Special purpose and generator turbines (API 612)

Condensing, multistage axial exhaustBelow 100 MW
Back pressure, multistageTo 50 MW
Back pressure, single stageTo 25 MW, horizontal or vertical
MarketsCogeneration, power, geothermal, combined cycle, refining and petrochemicals, fertilizer

Shin Nippon Machinery also builds API 614 lube oil systems for complete trains.

Steam turbine questions

What is the difference between API 611 and API 612?

API 611 covers general purpose steam turbines, typically single stage drives for pumps, fans and small compressors. API 612 covers special purpose turbines for critical, high power or high speed service.

Do you repair steam turbines from other manufacturers?

Yes. Our shop services Shin Nippon Machinery, Elliott and Dresser steam turbines, along with the gearboxes they drive.

Send the steam conditions and driven equipment data. We return a selection or repair scope.